- YORK®
- Commercial Equipment
- Ductless and VRF Systems
- Variable Refrigerant Flow Systems
- VRF Heat Recovery Air Source Outdoor Unit
VRF Heat Recovery Air Source Outdoor Unit
6-36 Ton Heat Recovery Systems (208/230V, 460V, 575V)
The YORK® VRF Heat-recovery Outdoor Unit offers an extended operating temperature range and can heat and cool spaces simultaneously.
Efficient, Cost-effective Comfort
YORK® Variable Refrigerant Flow (VRF) Heat-recovery Outdoor Units offer an extended operating temperature range: outdoor ambient temperature as low as -4°F (-20°C) in the cooling mode, utilizing a low ambient kit, and as low as -13°F (-25°C) in the heating mode. The simultaneous heating and cooling operating range of this VRF system is from -4°F to 75°F. Redesigned inverter scroll compressors, dual inverter compressors and power-saving demand control deliver efficient performance that translates to significant cost savings.
![Efficient, Cost-effective Comfort](https://tyco.widen.net/content/tm1jh1qhne/jpeg/JCHNA_imageleftcontentright_variable-refrigerant-flow-systems_638061090_3%20%281%29.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
Benefits
![Design Flexibility](https://tyco.widen.net/content/njsqw9xeui/jpeg/Sitecore%20Web%20Icons_Flexibility.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
DESIGN FLEXIBILITY
Up to 3,281 feet total pipe run and a vertical lift of 360 feet provide outstanding design versatility.
![Exceptional Energy Efficiency](https://tyco.widen.net/content/rlgmsuzv8q/jpeg/Sitecore%20Web%20Icons_Efficiency.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
EXCEPTIONAL ENERGY EFFICIENCY
Redesigned inverter scroll compressors deliver optimum efficiency at partial load conditions.
![Greater Project Opportunity](https://tyco.widen.net/content/usavvgfytk/jpeg/Sitecore%20Web%20Icons_Architects.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
GREATER PROJECT OPPORTUNITY
Impressive operating ranges and high capacities at low and high ambient temperatures meet diverse application requirements.
Features
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 tons
- Dual-inverter compressors standard in 8, 10, 12, 14 and 16 Ton units for increased efficiency
- Advanced defrost cycle operation in the heating mode
- Automatic judgement system for refrigerant amount to verify refrigerant charge is correct
- Long refrigerant piping lengths provide design flexibility – up to 3,281 feet total pipe run and a vertical lift of 360 feet when the outdoor unit(s) is above the indoor unit(s)
- Connection ratios up to 150% provide more design options
- Power-saving demand control for reduced peak load and energy savings
- Diagnostics and malfunction codes available at push of a control panel button
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Multiple fan speed settings
- 4 air volume settings – including Ultra Hi for higher ceilings
- 4-way airflow can be configured for 2-way or 3-way
- Removable front door panel for easy cleaning
- Wireless sensor with optional wireless zone controller
- Optional condensate pump
- Delivers up to 0.60 WG static pressure
- High-efficiency fan motor and multiple fan speed settings enhance performance and comfort
- Built-in condensate pump increases reliability
- Controls up to 64 groups of indoor units (maximum of 160 units)
- User-friendly touch-screen interface
- Set up to 10 on/off times per day