- YORK®
- Commercial Equipment
- Ductless and VRF Systems
- Variable Refrigerant Flow Systems
- VRF Mini Central Controller
VRF Mini Central Controller
CCM01
The YORK® VRF Mini Central Controller provides a high level of VRF system control through an easy-to-use, touch-screen interface and controls up to 32 groups of VRF indoor units.
- Individual zone control
- Independent cool and heat set points
- Basic central point on/off control
Outstanding VRF System Control
Manage up to 32 groups of VRF indoor units with the YORK® variable refrigerant flow (VRF) mini central controller. This intuitive controller has an easy-to-use, touch screen interface and all the features you need to conveniently oversee your VRF heating and cooling equipment.
![Outstanding VRF System Control](https://tyco.widen.net/content/pzcckrc6v3/jpeg/JCHNA_imageleftcontentright_variable-refrigerant-flow-systems_489110204_22.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
Benefits
![Precision Comfort](https://tyco.widen.net/content/nuirwndmrx/jpeg/Sitecore%20Web%20Icons_Comfort.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
PRECISION COMFORT
The mini controller enables fine control of air quantity and auto louvers settings.
![Simple Operation](https://tyco.widen.net/content/ua4yck5c4t/jpeg/Sitecore%20Web%20Icons_Simple%20-%20Easy%20Operations.jpeg?position=c&color=ffffffff&quality=80&u=txn4yx)
SIMPLE OPERATION
An intuitive, touch-screen interface and color-coded graphics make this controller easy to use.
![H-Link Ii Compatibility](https://tyco.widen.net/content/bv2upj7i5m/jpeg/Sitecore%20Web%20Icons_H-LINK%20II.jpg?color=ffffffff&u=ncoxvb&use=bsskz&position=c&quality=80)
H-LINK II COMPATIBILITY
Connect up to eight mini controllers to the H-Link II communication system for one centralized point of control.
Features
- Controls up to 32 groups of indoor units (maximum 160 units)
- Set up to 10 on/off times per day
- Standard external input/output terminals
- User-friendly touch-screen interface
- Color-coded graphics for quick reference
- External signals enable the following options: central operation/stop, demand control, emergency stop, central operation output and central alarm output
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 Tons
- 54.3" height
- Optional wireless remote controller, wired zone controller, wired central controller or wired BMS adapter(s)
- Systems are designed with dual heat recovery so heat can be recovered in both the water and refrigerant circuits
- Dual fuels can be used and include electricity for VRF units and natural gas or electricity for boiler
- Less refrigerant is required for water-source, VRF for easier compliance with ASHRAE Standard 15
- High-performance, high-efficiency heat exchanger
- Features efficient turbo fan for lower noise and a wide range of airflow settings
- Optional motion and radiant heat sensor for shutoff and activation in response to room occupancy
- Reduced integration expenses
- System organization customized to user needs
- Increased point data